Dimensions and Specifications
| Model | Viewing Area | Firebox Dimensions | Framing Dimensions |
| Switch 44 | 43 1/4” W x 15 7/8” H x 5 5/16” D43 1/4” W x 15 7/8” H x 5 5/16” D | 44 1/16” W x 24 7/8” H x 11 9/16” D44 1/16” W x 24 7/8” H x 11 9/16” D | 44 3/8” W x 25 1/4” H x 12” D44 3/8” W x 25 1/4” H x 12” D |
| Switch 56 | 55 1/4” W x 15 7/8” H x 5 5/16” D55 1/4” W x 15 7/8” H x 5 5/16” D | 56 1/16” W x 24 7/8” H x 11 9/16” D56 1/16” W x 24 7/8” H x 11 9/16” D | 56 3/8” W x 25 1/4” H x 12” D56 3/8” W x 25 1/4” H x 12” D |
| Switch 68 | 67 1/4” W x 15 7/8” H x 5 5/16” D67 1/4” W x 15 7/8” H x 5 5/16” D | 68 1/16” W x 24 7/8” H x 11 9/16” D68 1/16” W x 24 7/8” H x 11 9/16” D | 68 3/8” W x 25 1/4” H x 12” D68 3/8” W x 25 1/4” H x 12” D |
| Switch 80 | 79 1/4” W x 15 7/8” H x 5 5/16” D79 1/4” W x 15 7/8” H x 5 5/16” D | 80 1/16” W x 24 7/8” H x 11 9/16” D80 1/16” W x 24 7/8” H x 11 9/16” D | 80 3/8” W x 25 1/4” H x 12” D80 3/8” W x 25 1/4” H x 12” D |
| Switch 96 | 95 1/4” W x 15 7/8” H x 5 5/16” D95 1/4” W x 15 7/8” H x 5 5/16” D | 96 1/16” W x 24 7/8” H x 11 9/16” D96 1/16” W x 24 7/8” H x 11 9/16” D | 96 3/8” W x 25 1/4” H x 12” D96 3/8” W x 25 1/4” H x 12” D |
| Switch 120 | 119 1/4” W x 15 7/8” H x 5 5/16” D119 1/4” W x 15 7/8” H x 5 5/16” D | 120 1/16” W x 24 7/8” H x 11 9/16” D120 1/16” W x 24 7/8” H x 11 9/16” D | 120 3/8” W x 25 1/4” H x 12” D120 3/8” W x 25 1/4” H x 12” D |
Installation Location
Your appliance is a wall-mounted, recessed, and/or mantel installed appliance. Select a suitable location that is not susceptible to moisture and is away from drapes, furniture, and high traffic areas.
NOTE: Follow all National and local electrical codes.
This product includes a GLASS panel. Always use extreme caution when handlingglass. Failure to do so could result in personal injury or property damage.
Due to the many different materials used on different walls, it is highly recommended that you consult your local builder before you install this fireplace.
Remove all parts and hardware from the carton and place them on a clean, soft, dry surface. Parts and assembly steps are grouped for use. Check the parts list to make sure nothing is missing. Dispose of packaging materials properly. Please recycle whenever possible.
You will need the following tools (not included):
Phillips screwdriver, stud finder, level, tape measure, electric drill, 1/4” wood drill bit, hammer.
Built-in Installation
Optional Built-In styles shown below. See “Partial Recess Installation” or “Wall Mounted Installation” for additional mounting styles.
Switch Bay (3 Open Sides)

Switch Left Corner (2 Open Sides: Front and Left Corner)
Switch Right Corner (2 Open Sides: Front and Right Corner)

Switch Single Sided (1 Open Side)

Use a dedicated 20 Amp (or higher), 2-pole (for 10,000 BTUs) circuit breaker.
3 Sided Installation (Bay)
1. Prepare the framed opening according to the chart.
*Provide appropriate dedicated circuit for hardwire install at the top right of framed opening.

2. Install L Metal mounting brackets to the top and bottom of the fireplace with supplied screws.
3. Hardwire fireplace (see instructions)
4. Install the fireplace in the framed opening with a minimum 1 1/4” 32 mm drywall screws to secure the unit.

5. Mask the exposed fireplace during the drywall process. Install drywall to the drywall stops on the perimeter of the fire box. For more information on the drywall stops see the Product Guide.
6. Decorate according to media installation guide.
7. Install the side and front glass pieces according to installation diagram.
8. Install optional 5-pc. trim kit (sold separately.)

Fully Recessed Installation (Left/Right Corner)
1. Follow steps from the 3-sided installation instructions.
2. Remove the corresponding drywall stops according to your installation (in the example, the drywall stops on the left end would be removed.)
3. Install the side glass then the corresponding side cover according to your installation (the side glass must be installed before the metal side cover. See installation diagram.)

4. Wire fireplace (see instructions) for maximum heating power (10,000 BTUs) see optional wiring.
5. Install the fireplace in the framed opening with a minimum 1 1/4” 32 mm drywall screws to secure the unit.
6. Mask the exposed fireplace during the drywall process. Install drywall to the drywall stops on the perimeter of the fireplace. For more information on the drywall stops see the Product Guide.
7. Decorate according to media installation guide.
8. Install the remaining side glass and front glass according to installation diagram.
9. Install optional 5-pc. trim kit (sold separately.)

Fully Recessed Installation (Single Sided)
1. Follow steps from the 3 sided installation instructions.
2. Remove the drywall stops on both sides of the fire unit.
3. Install the side glass then side covers on both sides of the fire unit (the side glass must be installed before the metal side cover. See installation diagram.)
4. Install the fire unit in the framed opening with a minimum 1 1/4” 32 mm drywall screws to secure the unit.

5. Mask the exposed fireplace during the drywall process. Install drywall to the drywall stops on the perimeter of the fireplace. For more information on the drywall stops see the Product Guide.
6. Decorate according to media installation guide.
7. Install the front glass according to installation diagram.
8. Installation optional: 1-pc trim kit (included.)

Half Recessed Installation
1. This installation is optimized for a 2x4 framed wall. Prepare the framed opening according to the height and width of the chart.
*Provide appropriate dedicated circuit for hardwire install at the top right of framed opening.

2. Install L Metal Nailing Flanges to the top and bottom of the fireplace.
3. Hardwire fireplace (see instructions).
4. Install the fire unit in the framed opening with a minimum 1 1/4” 32 mm drywall screws to secure the unit.

5. Mask the exposed viewing area of fireplace during this process. Install drywall, tile or material of your choice to the drywall stops on the perimeter of the fireplace. For more information on the drywall stops see the Product Guide.
6. Decorate according to media installation guide.
7. Install the side and front glass pieces according to installation diagram.
8. Finish fireplace with your desired decorative.

Outdoor Installation Requirements
The Switch Electric Series have been tested and approved for installation outdoors under a patio cover and away from direct water contact or direct sun light.
Switch Electric Series standard warranty applies if installed per instructions. All electrical wiring shall be to local building codes. Consult professional installers before installation. Approved installations are as noted below.
Front Protection
Patio roof overhang must be 50% (or more) of the height of the patio roof from bottom of fireplace.
If: H=6’
Then: OD=3’ minimum (6’ x 50%=3’)
Note 1: Base of fireplace must be 2” (minimum) above floor.
Note 2: H taken from bottom of fireplace.

Side Protection
Side distance (SD) must be 50% (or more) of the height(H).
If: H=6’
Then: SD=3’ minimum (6’ x 50%=3’)
Note: H taken from bottom of fireplace.